Difference between revisions of "Fitlet2 Errata Notes"
From fit-PC wiki
Line 15: | Line 15: | ||
* '''Fix''': Fixed in fitlet2 with serial number 1180903-xxxxx and later | * '''Fix''': Fixed in fitlet2 with serial number 1180903-xxxxx and later | ||
− | == | + | == FITLET2ERR003: fitlet2 does not enter S5 state (off) but only S3 state (sleep) == |
* '''Date''': 23-Oct-2018 | * '''Date''': 23-Oct-2018 | ||
* '''Symptom''': When shutting-down fitlet2 from software or by pressing the power button fitlet2 enters S3 (sleep) state instead of S5 (off) state | * '''Symptom''': When shutting-down fitlet2 from software or by pressing the power button fitlet2 enters S3 (sleep) state instead of S5 (off) state | ||
Line 23: | Line 23: | ||
* '''Fix''': A new version of PMIC used in fitlet2 with serial number TBD and later | * '''Fix''': A new version of PMIC used in fitlet2 with serial number TBD and later | ||
− | Note: Amber LED on power button stays on at S5. This is unrelated to | + | Note: Amber LED on power button stays on at S5. This is unrelated to FITLET2ERR003 |
[[category:fitlet2]] | [[category:fitlet2]] | ||
[[category:errata notes]] | [[category:errata notes]] |
Revision as of 16:48, 23 October 2018
FITLET2ERR001: Power button action cannot be configured in Windows 10
- Date: 27-May-2018
- Symptom: Configuring Power button action through Windows 10 control panel has no effect
- Applies to: fitlet2 rev 1.1
- Cause: Erratum in power management integrated circuit
- Workaround: Control power modes from software
- Fix: Fixed in fitlet2 rev 1.2 with with BIOS version FLT2.0.40.01.00
FITLET2ERR002: No eMMC support
- Date: 2-Sep-2018
- Symptom: eMMC module is not identified
- Applies to: fitlet2 with serial number 1180902-xxxxx or earlier
- Cause: Circuit of eMMC interface is not assembled on SBC
- Workaround: Use M.2 SATA storage
- Fix: Fixed in fitlet2 with serial number 1180903-xxxxx and later
FITLET2ERR003: fitlet2 does not enter S5 state (off) but only S3 state (sleep)
- Date: 23-Oct-2018
- Symptom: When shutting-down fitlet2 from software or by pressing the power button fitlet2 enters S3 (sleep) state instead of S5 (off) state
- Applies to: fitlet2 rev 1.1 with serial number TBD or earlier
- Cause: An erratum in fitlet2 PMIC
- Workaround: Long press on power button shuts down fitlet2 completely
- Fix: A new version of PMIC used in fitlet2 with serial number TBD and later
Note: Amber LED on power button stays on at S5. This is unrelated to FITLET2ERR003