Changes
==TEL-SERX4==
* Type: '''SERIAL IO TELCOM'''* Config name: '''FHA'''* Compulab part number: '''FT.H-SER4'''
* Interface: '''USB 2.0'''
* TRIP" : '''2,3,4,5,6,7,7B,8,9'''
* Stacking: '''A, C'''
* Features: '''4x RS232 / RS485 with DB9 connectors'''
[[File:TEL-SER4 6.png|200px]]
TEL-SERX4 Provides USB to Multiprotocol(RS-232, RS-485-Half Duplex, RS485-Full Duplex) serial connection (up to 4 Ports per TEL).
* Simple USB Connection protocol
* Supports Multiprotocol implementation on one DB9 Connector.
* Individually enabled between RS-232 or RS485 ports.
* Build-in Termination resistor.
* Protocol switching using Onboard switches or using I2C expander
USB <--> USB HUB <---> RS-232 / RS-485 (Port A) - Native DB-9 Port
RS-232 / RS-485 (Port B)
RS-232 / RS-485 (Port C)
RS-232 / RS-485 (Port D)
RS-485 - Globally enable Termination resistor. - User Switchable
- Globally Switched Between Half Duplex and Full-Duplex mode. - User Switchable
TEL-SERX4 is utilizing a USB2 interface
Multiple TEL-SERX4 cards can be installed in a system
===Specifications===
===InstructionsConfiguration ======= Two Configuration method of the device====* Onboard switches SW1 - PORTA: ON->RS-232 OFF->RS-485 - Native on board Port SW2 - PORTB: ON->RS-232 OFF->RS-485 SW3 - PORTC: ON->RS-232 OFF->RS-485 SW4 - PORTD: ON->RS-232 OFF->RS-485 SW7 - ON->RS-485 Half Duplex OFF->RS-485 Full-Duplex - Port A-D SW5 - ON->Enables Termination resistor RS-485-Half Duplex - Port A-D SW6 - ON->Enables Termination Resistor RS-485-Full Duplex - Port A-D * I2C GPIO expander(PCA9555) that is located on I2C address 0X27. I/O,0.0 -- Port A: High: RS-232, Low: RS-485 I/O,0.1 -- Port B: High: RS-232, Low: RS-485 I/O,0.2 -- Port C: High: RS-232, Low: RS-485 I/O,0.3 -- Port D: High: RS-232, Low: RS-485 I/O,0.4 -- NC I/O,0.5 -- NC I/O,0.6 -- NC I/O,0.7 -- Global: High RS-485 Half Duplex, Low: RS-485 Full Duplex I/O,1.0 -- Port A: High RS-485 Termination enabled on Half Duplex Lines I/O,1.1 -- Port B: High RS-485 Termination enabled on Half Duplex Lines I/O,1.2 -- Port C: High RS-485 Termination enabled on Half Duplex Lines I/O,1.3 -- Port D: High RS-485 Termination enabled on Half Duplex Lines I/O,1.4 -- Port A: High RS-485 Termination enabled on Full-Duplex Lines I/O,1.5 -- Port B: High RS-485 Termination enabled on Full-Duplex Lines I/O,1.6 -- Port C: High RS-485 Termination enabled on Full-Duplex Lines I/O,1.7 -- Port D: High RS-485 Termination enabled on Full-Duplex Lines === Open source hardware and software ===* Complete hardware design files are available* Complete firmware is available == Connection requirements ===== Pinout ==={||-| [[File:TEL-SERDB9_DB9_pinout_diagram.png|thumb|none|600px | DB-9 Pinout]]| [[File:TEL-SERDB9_DB9_Switch_board location.png|thumb|none|273px | Switch Location Diagram]]|}
<!--
===Instructions=== * [https://fit-iot.com/files/mechanical/FACETSTELS/FCTEL-CEMSERX4/Installation-instructions/fitlet2-FCTEL-CEMSERX4-installation-instructions.pdf fitlet2 FCTEL-CEM SERX4 installation instructions]-->
===Production files===
<!--
*3D 360<sup>0</sup> model
-->