Changes

Jump to: navigation, search

Fitlet2 Errata Notes

1,080 bytes added, 08:00, 23 August 2021
/* FITLET2ERR002: No eMMC support */
* '''Workaround''': Use M.2 SATA storage
* '''Fix''': Fixed in fitlet2 with SBC serial number 1180903-xxxxx and later
 
Note: <span style="color: rgb(255, 0, 0)">'''Since March 2020 eMMC interface in fitlet2 is disabled'''</span>.
== FITLET2ERR003: fitlet2 does not enter S5 state (off) but only S3 state (sleep) ==
* '''Fix''': Fixed in EB-M2SATA Rev 1.3 expected to be available now (since Jan-2020).
 
== FITLET2ERR008: Interoperability issue with some models of M.2 SATA SSD ==
* '''Date''': 5-MAR-2020
* '''Symptom''': Inconsistent behavior of M.2 SSD. e.g. fitlet2 fails to identify an SSD (permanently or intermittently)
* '''Applies to''': fitlet2 with M.2 SSD of specific models. See [[Compatibility matrix of M.2 SSD models to IPC3 / fitlet2 / Airtop3 | SSD compatibility matrix]] for details
* '''Cause''': fitlet2 implements eMMC interface on M.2 key-M unused pins. The same pins are sometimes used for vendor specific functionality in some SSD models. This can lead to unexpected behavior of these SSDs
* '''Workaround''': Opt for a validated SSD | [https://fit-iot.com/forum/viewtopic.php?f=170&t=6865 insulating M.2 SSD pins]
* '''Fix''': fitlet2 volume orders placed after 5-Mar-2020 will be supplied with the eMMC interface disconnected. As of Mar-2020 Compulab is researching the problem. If additional solutions are found this erratum will be updated.
[[category:fitlet2]]
[[category:errata notes]]
865