Difference between revisions of "FACE Modules:FM-SER"
From fit-PC wiki
Line 12: | Line 12: | ||
* Two independent CAN bus controllers implement CAN V2.0B at rate of up to 1Mbps each | * Two independent CAN bus controllers implement CAN V2.0B at rate of up to 1Mbps each | ||
* Isolated PHY with rated isolation voltage of 2.5 kV RMS | * Isolated PHY with rated isolation voltage of 2.5 kV RMS | ||
+ | |||
+ | {| style="width: 100%; height: 200px;" border="1" cellpadding="10" cellspacing="0" align="center" | ||
+ | ! style="font-weight: bold;" | Connectivity | ||
+ | ! style="font-weight: bold;" | Specifications | ||
+ | |- | ||
+ | | RS232 / RS485 / RS4221 | ||
+ | | 6x RJ-11 jacks functioning as RS2322, as | ||
+ | half3/full-duplex RS485 or RS422 serial ports; | ||
+ | |- | ||
+ | | CAN bus | ||
+ | | 2x RJ-45 jacks functioning as an isolated Controller | ||
+ | Area Network (CAN) bus | ||
+ | |} | ||
+ | |||
+ | Notes: | ||
+ | # The default standard can be configured by jumper E1. See section Serial Ports Configuration. | ||
+ | # FM-SER is classified as DTE (Data Terminal Equipment) in terms of RS232 standard definition. | ||
+ | # RS485 half-duplex mode requires special HW/SW adaptation | ||
=== Block Diagram === | === Block Diagram === |
Revision as of 11:14, 8 September 2015
Contents
FM-SER Module
FM-SER FACE Module provide various serial connectivity solution and compatible with several Compulab systems. Refer to Compatibility Matrix for products fit.
Highlights
- High performance UARTS
- Asynchronous baud rates up to 15Mbps
- 128-byte deep TX/RX FIFOs
- Advanced FIFO fill management
- RS232, RS485, RS422 operation
- Programmable RS485 turn-around delay
- 450 through 950 software compatibility
- Two independent CAN bus controllers implement CAN V2.0B at rate of up to 1Mbps each
- Isolated PHY with rated isolation voltage of 2.5 kV RMS
Connectivity | Specifications |
---|---|
RS232 / RS485 / RS4221 | 6x RJ-11 jacks functioning as RS2322, as
half3/full-duplex RS485 or RS422 serial ports; |
CAN bus | 2x RJ-45 jacks functioning as an isolated Controller
Area Network (CAN) bus |
Notes:
- The default standard can be configured by jumper E1. See section Serial Ports Configuration.
- FM-SER is classified as DTE (Data Terminal Equipment) in terms of RS232 standard definition.
- RS485 half-duplex mode requires special HW/SW adaptation
Block Diagram
Schematics
Layout
Mechanics
Assembly