Difference between revisions of "Fitlet2 Errata Notes"
From fit-PC wiki
(→FITLET2ERR002: No eMMC support) (change visibility) |
|||
(25 intermediate revisions by 2 users not shown) | |||
Line 1: | Line 1: | ||
+ | __TOC__ | ||
+ | |||
== FITLET2ERR001: Power button action cannot be configured in Windows 10 == | == FITLET2ERR001: Power button action cannot be configured in Windows 10 == | ||
* '''Date''': 27-May-2018 | * '''Date''': 27-May-2018 | ||
Line 5: | Line 7: | ||
* '''Cause''': Erratum in power management integrated circuit | * '''Cause''': Erratum in power management integrated circuit | ||
* '''Workaround''': Control power modes from software | * '''Workaround''': Control power modes from software | ||
− | * '''Fix''': Fixed in fitlet2 rev 1.2 | + | ** [[fitlet2 Rev1.1 Power button action workaround for Windows 10]] |
+ | * '''Fix''': Fixed in fitlet2 rev 1.2 with with BIOS version FLT2.0.40.01.00 | ||
== FITLET2ERR002: No eMMC support == | == FITLET2ERR002: No eMMC support == | ||
* '''Date''': 2-Sep-2018 | * '''Date''': 2-Sep-2018 | ||
* '''Symptom''': eMMC module is not identified | * '''Symptom''': eMMC module is not identified | ||
− | * '''Applies to''': fitlet2 with serial number 1180902-xxxxx or earlier | + | * '''Applies to''': fitlet2 with SBC serial number 1180902-xxxxx or earlier |
* '''Cause''': Circuit of eMMC interface is not assembled on SBC | * '''Cause''': Circuit of eMMC interface is not assembled on SBC | ||
* '''Workaround''': Use M.2 SATA storage | * '''Workaround''': Use M.2 SATA storage | ||
− | * '''Fix''': Fixed in fitlet2 with serial number 1180903-xxxxx and later | + | * '''Fix''': Fixed in fitlet2 with SBC serial number 1180903-xxxxx and later |
+ | |||
+ | Note: Since Mar-2020 eMMC interface in fitlet2 is disabled. | ||
+ | |||
+ | == FITLET2ERR003: fitlet2 does not enter S5 state (off) but only S3 state (sleep) == | ||
+ | * '''Date''': 23-Oct-2018 | ||
+ | * '''Symptom''': When shutting-down fitlet2 from software or by pressing the power button fitlet2 enters S3 (sleep) state instead of S5 (off) state | ||
+ | * '''Applies to''': fitlet2 rev 1.1 with serial number 1180724-xxxxx or earlier | ||
+ | * '''Cause''': An erratum in fitlet2 PMIC | ||
+ | * '''Workaround''': Long press on power button shuts down fitlet2 completely | ||
+ | * '''Fix''': A new version of PMIC used in fitlet2 with serial number 1180725-00001 and later | ||
+ | |||
+ | Note: Amber LED on power button stays on at S5. This is unrelated to FITLET2ERR003 | ||
+ | |||
+ | == FITLET2ERR004: Marginal edge-connector quality in FC-PCI == | ||
+ | * '''Date''': 6-Jan-2019 | ||
+ | * '''Symptom''': Devices installed on FC-PCI (Modem / SSD / Wi-Fi adapter / mini-PCIe card) may malfunction. There is no record of permanent damage to devices installed on FC-PCI | ||
+ | * '''Applies to''': fitlet2 with FC-PCI rev 1.0 | ||
+ | * '''Cause''': Marginal quality of FC-PCI edge connector | ||
+ | * '''Workaround''': Covered under warranty. Compulab will replace FC-PCI FACET Cards exhibiting errors | ||
+ | * '''Fix''': Compulab redesigns FC-PCI FACET Card (rev 1.1) to improve edge connector's quality | ||
+ | |||
+ | Note: The problem is specific to FC-PCI and does not apply to other FACET Cards | ||
+ | |||
+ | == FITLET2ERR005: Built in Ethernet port is disappearing on start-up == | ||
+ | * '''Date''': 28-Apr-2019 | ||
+ | * '''Symptom''': One of the built in Ethernet ports is disappearing on start-up. | ||
+ | * '''Applies to''': fitlet2 configured with either - FC-PCI Rev1.0-1.1, FC-CEM Rev1.0, FC-POED Rev1.0. | ||
+ | * '''Cause''': In FC-PCI Rev1.0-1.1, FC-CEM Rev1.0 and FC-POED Rev1.0 rails 3.3V_A and 3.3V_S are connected in way which affects power sequencing. As a result, in rare cases on-board Ethernet controller's reset is released before PCI bus initialization is complete which results in Ethernet controller being unrecognized. | ||
+ | * '''Workaround''': None | ||
+ | * '''Fix''': Fix applied to FC-PCI Rev1.2, FC-CEM Rev1.1, FC-POED Rev1.1. | ||
+ | |||
+ | == FITLET2ERR006: RS-485 half duplex not working on fitlet2 configured with FC-SCG== | ||
+ | * '''Date''': 28-Apr-2019 | ||
+ | * '''Symptom''': RS-485 half duplex is not working on fitlet2 configured with FC-SCG. | ||
+ | * '''Applies to''':fitlet2 configured with FC-SCG Rev1.0 | ||
+ | * '''Cause''': In FC-SCG Rev1.0 the TXDEN signal that controls RX/TX direction is disconnected. As a result RS485 half-duplex does not function. | ||
+ | * '''Workaround''': None | ||
+ | * '''Fix''': Fix applied to FC-SCG Rev1.1 | ||
+ | |||
+ | == FITLET2ERR007: Disk errors with EB-M2SATA rev 1.1 == | ||
+ | * '''Date''': 11-SEP-2019 | ||
+ | * '''Symptom''': fitlet2 with a 2.5" hard disk / SSD connected through EB-M2SATA fails to boot or exhibit other disk related errors. | ||
+ | * '''Applies to''': fitlet2 with EB-M2SATA Rev1.1 adapter. | ||
+ | * '''Cause''': Marginal SATA signal quality in EB-M2SATA. | ||
+ | * '''Workaround 1''': The problem was observed with some hard disks and SSD's. See [https://docs.google.com/spreadsheets/d/11RPOke7sZUF1iJ41UR2IfCuDMTMhpvrXjvZaG4ei8aU/edit?usp=sharing this list] for validated hard disks and SSD's. | ||
+ | * '''Workaround 2''': According to Compulab's tests, forcing SATA interface to SATA2 300MHz and not allowing SATA3 600 MHz resolves the problem; A BIOS version with SATA2 forced is available - [http://fit-pc.com/download/fitlet2/bios/customers/foreveroceans/FLT2.0.46.01.26.zip HERE] | ||
+ | **To install, follow the [http://fit-pc.com/wiki/index.php?title=Fitlet2:_BIOS_Update fitlet2 BIOS update manual] | ||
+ | |||
+ | * '''Fix''': Fixed in EB-M2SATA Rev 1.3 expected to be available now (since Jan-2020). | ||
+ | |||
+ | == FITLET2ERR008: Interoperability issue with some models of M.2 SATA SSD == | ||
+ | * '''Date''': 5-MAR-2020 | ||
+ | * '''Symptom''': Inconsistent behavior of M.2 SSD. e.g. fitlet2 fails to identify an SSD (permanently or intermittently) | ||
+ | * '''Applies to''': fitlet2 with M.2 SSD of specific models. See [[Compatibility matrix of M.2 SSD models to IPC3 / fitlet2 / Airtop3 | SSD compatibility matrix]] for details | ||
+ | * '''Cause''': fitlet2 implements eMMC interface on M.2 key-M unused pins. The same pins are sometimes used for vendor specific functionality in some SSD models. This can lead to unexpected behavior of these SSDs | ||
+ | * '''Workaround''': Opt for a validated SSD | [https://fit-iot.com/forum/viewtopic.php?f=170&t=6865 insulating M.2 SSD pins] | ||
+ | * '''Fix''': fitlet2 volume orders placed after 5-Mar-2020 will be supplied with the eMMC interface disconnected. As of Mar-2020 Compulab is researching the problem. If additional solutions are found this erratum will be updated. | ||
[[category:fitlet2]] | [[category:fitlet2]] | ||
[[category:errata notes]] | [[category:errata notes]] |
Revision as of 08:12, 27 May 2020
Contents
- 1 FITLET2ERR001: Power button action cannot be configured in Windows 10
- 2 FITLET2ERR002: No eMMC support
- 3 FITLET2ERR003: fitlet2 does not enter S5 state (off) but only S3 state (sleep)
- 4 FITLET2ERR004: Marginal edge-connector quality in FC-PCI
- 5 FITLET2ERR005: Built in Ethernet port is disappearing on start-up
- 6 FITLET2ERR006: RS-485 half duplex not working on fitlet2 configured with FC-SCG
- 7 FITLET2ERR007: Disk errors with EB-M2SATA rev 1.1
- 8 FITLET2ERR008: Interoperability issue with some models of M.2 SATA SSD
FITLET2ERR001: Power button action cannot be configured in Windows 10
- Date: 27-May-2018
- Symptom: Configuring Power button action through Windows 10 control panel has no effect
- Applies to: fitlet2 rev 1.1
- Cause: Erratum in power management integrated circuit
- Workaround: Control power modes from software
- Fix: Fixed in fitlet2 rev 1.2 with with BIOS version FLT2.0.40.01.00
FITLET2ERR002: No eMMC support
- Date: 2-Sep-2018
- Symptom: eMMC module is not identified
- Applies to: fitlet2 with SBC serial number 1180902-xxxxx or earlier
- Cause: Circuit of eMMC interface is not assembled on SBC
- Workaround: Use M.2 SATA storage
- Fix: Fixed in fitlet2 with SBC serial number 1180903-xxxxx and later
Note: Since Mar-2020 eMMC interface in fitlet2 is disabled.
FITLET2ERR003: fitlet2 does not enter S5 state (off) but only S3 state (sleep)
- Date: 23-Oct-2018
- Symptom: When shutting-down fitlet2 from software or by pressing the power button fitlet2 enters S3 (sleep) state instead of S5 (off) state
- Applies to: fitlet2 rev 1.1 with serial number 1180724-xxxxx or earlier
- Cause: An erratum in fitlet2 PMIC
- Workaround: Long press on power button shuts down fitlet2 completely
- Fix: A new version of PMIC used in fitlet2 with serial number 1180725-00001 and later
Note: Amber LED on power button stays on at S5. This is unrelated to FITLET2ERR003
FITLET2ERR004: Marginal edge-connector quality in FC-PCI
- Date: 6-Jan-2019
- Symptom: Devices installed on FC-PCI (Modem / SSD / Wi-Fi adapter / mini-PCIe card) may malfunction. There is no record of permanent damage to devices installed on FC-PCI
- Applies to: fitlet2 with FC-PCI rev 1.0
- Cause: Marginal quality of FC-PCI edge connector
- Workaround: Covered under warranty. Compulab will replace FC-PCI FACET Cards exhibiting errors
- Fix: Compulab redesigns FC-PCI FACET Card (rev 1.1) to improve edge connector's quality
Note: The problem is specific to FC-PCI and does not apply to other FACET Cards
FITLET2ERR005: Built in Ethernet port is disappearing on start-up
- Date: 28-Apr-2019
- Symptom: One of the built in Ethernet ports is disappearing on start-up.
- Applies to: fitlet2 configured with either - FC-PCI Rev1.0-1.1, FC-CEM Rev1.0, FC-POED Rev1.0.
- Cause: In FC-PCI Rev1.0-1.1, FC-CEM Rev1.0 and FC-POED Rev1.0 rails 3.3V_A and 3.3V_S are connected in way which affects power sequencing. As a result, in rare cases on-board Ethernet controller's reset is released before PCI bus initialization is complete which results in Ethernet controller being unrecognized.
- Workaround: None
- Fix: Fix applied to FC-PCI Rev1.2, FC-CEM Rev1.1, FC-POED Rev1.1.
FITLET2ERR006: RS-485 half duplex not working on fitlet2 configured with FC-SCG
- Date: 28-Apr-2019
- Symptom: RS-485 half duplex is not working on fitlet2 configured with FC-SCG.
- Applies to:fitlet2 configured with FC-SCG Rev1.0
- Cause: In FC-SCG Rev1.0 the TXDEN signal that controls RX/TX direction is disconnected. As a result RS485 half-duplex does not function.
- Workaround: None
- Fix: Fix applied to FC-SCG Rev1.1
FITLET2ERR007: Disk errors with EB-M2SATA rev 1.1
- Date: 11-SEP-2019
- Symptom: fitlet2 with a 2.5" hard disk / SSD connected through EB-M2SATA fails to boot or exhibit other disk related errors.
- Applies to: fitlet2 with EB-M2SATA Rev1.1 adapter.
- Cause: Marginal SATA signal quality in EB-M2SATA.
- Workaround 1: The problem was observed with some hard disks and SSD's. See this list for validated hard disks and SSD's.
- Workaround 2: According to Compulab's tests, forcing SATA interface to SATA2 300MHz and not allowing SATA3 600 MHz resolves the problem; A BIOS version with SATA2 forced is available - HERE
- To install, follow the fitlet2 BIOS update manual
- Fix: Fixed in EB-M2SATA Rev 1.3 expected to be available now (since Jan-2020).
FITLET2ERR008: Interoperability issue with some models of M.2 SATA SSD
- Date: 5-MAR-2020
- Symptom: Inconsistent behavior of M.2 SSD. e.g. fitlet2 fails to identify an SSD (permanently or intermittently)
- Applies to: fitlet2 with M.2 SSD of specific models. See SSD compatibility matrix for details
- Cause: fitlet2 implements eMMC interface on M.2 key-M unused pins. The same pins are sometimes used for vendor specific functionality in some SSD models. This can lead to unexpected behavior of these SSDs
- Workaround: Opt for a validated SSD | insulating M.2 SSD pins
- Fix: fitlet2 volume orders placed after 5-Mar-2020 will be supplied with the eMMC interface disconnected. As of Mar-2020 Compulab is researching the problem. If additional solutions are found this erratum will be updated.