* Type: '''COM'''
 
* Type: '''COM'''
 
* Config name: '''FHA'''
 
* Config name: '''FHA'''
 +
* Compulab part number: '''FT.HA-SER1'''
 
* Interface: '''USB 2.0'''
 
* Interface: '''USB 2.0'''
* TRIP" '''2,3,4,5,6,7,7B,8,9'''
+
* TRIP: '''2,3,4,5,6,7,7B,8,9'''
 
* Stacking: '''A, C'''
 
* Stacking: '''A, C'''
 
* Features:  '''1x RS232 by DB9'''
 
* Features:  '''1x RS232 by DB9'''
Line 16: Line 17:
 
* Each port supports RS232, RS485 half/full duplex and can be configured independently.
 
* Each port supports RS232, RS485 half/full duplex and can be configured independently.
 
* Over 20 ports can be installed.
 
* Over 20 ports can be installed.
 
+
<!--
=<!--==Instructions===
+
===Instructions===
  
 
* [https://fit-iot.com/files/mechanical/TELS/TEL-SERX1/Installation-instructions/fitlet2-TEL-SERX1-installation-instructions.pdf fitlet2 TEL-SERX1 installation instructions]
 
* [https://fit-iot.com/files/mechanical/TELS/TEL-SERX1/Installation-instructions/fitlet2-TEL-SERX1-installation-instructions.pdf fitlet2 TEL-SERX1 installation instructions]
 
+
-->
 
===Production files===
 
===Production files===
  
*Schematics
+
<b><u>Schematics</u></b>
  
**[https://fit-iot.com/files/mechanical/TELS/TEL-SERX1/Schematics/TEL-SERX1-1_0-Schematic.zip TEL-SERX1 Rev1.0 Schematic files]
+
*[https://fit-iot.com/files/tensor-pc/TELs/FT.HA-SER1/FT.HA-SER1_V1_0_1_Schematics_8000011301.zip TEL-SERX1 Rev1.0.1 Schematic files]
  
*Assembly
+
<b><u>Assembly</u></b>
  
**[https://fit-iot.com/files//mechanical/TELS/TEL-SERX1/Assembly/TEL-SERX1-1_0-Assembly.zip TEL-SERX1 Rev1.0 Assembly files]
+
*[https://fit-iot.com/files/tensor-pc/TELs/FT.HA-SER1/FT.HA-SER1_V1_0_1_Assembly_drawings_8050011301.zip TEL-SERX1 Rev1.0.1 Assembly files]
  
*Layout
+
<b><u>Layout</u></b>
  
**[https://fit-iot.com/files/mechanical/TELS/TEL-SERX1/Layout/TEL-SERX1-1_0-Layout.zip TEL-SERX1 Rev1.0 Layout files]
+
*[https://fit-iot.com/files/tensor-pc/TELs/FT.HA-SER1/FT.HA-SER1_V1_0_1_Layout_8030011301.zip TEL-SERX1 Rev1.0.1 Layout files]
  
*Mechanical
+
<b><u>Mechanical</u></b>
  
**[https://fit-iot.com/files/mechanical/TELS/TEL-SERX1/Mechanical/TEL-SERX1.DXF TEL-SERX1 Mechanical - DXF]<br>
+
*[https://fit-iot.com/files/tensor-pc/TELs/FT.HA-SER1/FT.HA-SER1_V1_0_1_Mechanical_8010011301.zip TEL-SERX1 Rev1.0.1 Mechanical - DXF]<br>
**[https://fit-iot.com/files/mechanical/TELS/TEL-SERX1/Mechanical/TEL-SERX1.PDF TEL-SERX1 Mechanical - PDF]
+
<!--
  
 
*3D 360<sup>0</sup> model
 
*3D 360<sup>0</sup> model

Latest revision as of 13:56, 25 August 2021

TEL-SERX1

  • Type: COM
  • Config name: FHA
  • Compulab part number: FT.HA-SER1
  • Interface: USB 2.0
  • TRIP: 2,3,4,5,6,7,7B,8,9
  • Stacking: A, C
  • Features: 1x RS232 by DB9


TEL-HA-SER.png


Specifications

  • Using DB9 connector.
  • Each port supports RS232, RS485 half/full duplex and can be configured independently.