Last modified on 12 February 2018, at 08:21

Fitlet Errata Notes

Revision as of 08:21, 12 February 2018 by Irads (Talk | contribs) (FITLETERR002: USB current limit)

(change visibility) (diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)

FITLETERR001: SIM slot

  • Date: 29-Apr-2015
  • Symptom: SIM card is not detected while in micro SIM slot
  • Applies to revision(s): 1.0 to 1.1
  • Cause: Incorrect SIM slot pin routing
  • Workaround: RMA for manual patch
  • Fix: Fixed in revision 1.2

FITLETERR002: USB current limit

  • Date: 6-Oct-2015
  • Symptom: When connecting high power USB device, fitlet may reboot. Most likely to happen on insertion of the device.
  • Applies to revision(s): 1.0 to 1.3
  • Cause: Incorrect routing of USB current-limiter is causing current-limiting of USB to malfunction. High current of USB device may reset fitlet.
  • Workaround: Low-power USB devices – keyboard, mouse, webcam, thumb drive, WiFi adapter are not affected. To work around the problem with USB hard disks plug the disk when fitlet is off or use a powered USB hub.
  • Fix: Will be fixed in revision 1.4