Difference between revisions of "AMT configuration"

From fit-PC wiki
Jump to: navigation, search
(Created page with "* This guide instructs how to configure Intel AMT. * it applies to models: IPC3 | Airtop2 | Airtop3. '''AMT configuration''' 1. Power on the machine and press CTRL+P at the...")   (change visibility)
(No difference)

Revision as of 13:42, 21 May 2019

  • This guide instructs how to configure Intel AMT.
  • it applies to models: IPC3 | Airtop2 | Airtop3.

AMT configuration

1. Power on the machine and press CTRL+P at the splash screen to enter MEBx BIOS. 2. Enter AMT configuration settings, you'll be prompted to enter a password. 3. Change the default password. The default password is "admin". The new password has the comply with the following policies: - At least 8 characters - At least one digit character (eg. 0, 1, … 9) - At least one non-alpha-numeric character (e.g. !, $, ;) excluding colon, comma or quotes. - At least one lower-case letter (a, b, c, d...) - At least one upper case letter (A, B, C, D,...)

  • optional: The AMT system uses DHCP to configure an IP Address.
  • If you do not have a DHCP server you can configure a static IP within Intel AMT Configuration > Network Setup > TCP/IP Settings.

4. After completing network configuration the Web interface should be available at port 16992 (http://<IP>:16992/). Log in once to verify that it is available and properly configured.