Difference between revisions of "Fitlet2 Errata Notes"

From fit-PC wiki
Jump to: navigation, search
(FITLET2ERR002: No eMMC support)   (change visibility)
Line 12: Line 12:
 
* '''Date''': 2-Sep-2018
 
* '''Date''': 2-Sep-2018
 
* '''Symptom''': eMMC module is not identified
 
* '''Symptom''': eMMC module is not identified
* '''Applies to''': fitlet2 with serial number 1180902-xxxxx or earlier
+
* '''Applies to''': fitlet2 with SBC serial number 1180902-xxxxx or earlier
 
* '''Cause''': Circuit of eMMC interface is not assembled on SBC
 
* '''Cause''': Circuit of eMMC interface is not assembled on SBC
 
* '''Workaround''': Use M.2 SATA storage
 
* '''Workaround''': Use M.2 SATA storage
* '''Fix''': Fixed in fitlet2 with serial number 1180903-xxxxx and later
+
* '''Fix''': Fixed in fitlet2 with SBC serial number 1180903-xxxxx and later
  
 
== FITLET2ERR003: fitlet2 does not enter S5 state (off) but only S3 state (sleep) ==
 
== FITLET2ERR003: fitlet2 does not enter S5 state (off) but only S3 state (sleep) ==

Revision as of 13:49, 4 November 2018

FITLET2ERR001: Power button action cannot be configured in Windows 10

  • Date: 27-May-2018
  • Symptom: Configuring Power button action through Windows 10 control panel has no effect
  • Applies to: fitlet2 rev 1.1
  • Cause: Erratum in power management integrated circuit
  • Workaround: Control power modes from software
  • Fix: Fixed in fitlet2 rev 1.2 with with BIOS version FLT2.0.40.01.00

FITLET2ERR002: No eMMC support

  • Date: 2-Sep-2018
  • Symptom: eMMC module is not identified
  • Applies to: fitlet2 with SBC serial number 1180902-xxxxx or earlier
  • Cause: Circuit of eMMC interface is not assembled on SBC
  • Workaround: Use M.2 SATA storage
  • Fix: Fixed in fitlet2 with SBC serial number 1180903-xxxxx and later

FITLET2ERR003: fitlet2 does not enter S5 state (off) but only S3 state (sleep)

  • Date: 23-Oct-2018
  • Symptom: When shutting-down fitlet2 from software or by pressing the power button fitlet2 enters S3 (sleep) state instead of S5 (off) state
  • Applies to: fitlet2 rev 1.1 with serial number 1180724-xxxxx or earlier
  • Cause: An erratum in fitlet2 PMIC
  • Workaround: Long press on power button shuts down fitlet2 completely
  • Fix: A new version of PMIC used in fitlet2 with serial number 1180725-00001 and later
Note: Amber LED on power button stays on at S5. This is unrelated to FITLET2ERR003