Difference between revisions of "Fitlet2 Errata Notes"
From fit-PC wiki
(→FITLET2ERR002: No eMMC support) (change visibility) |
|||
Line 12: | Line 12: | ||
* '''Date''': 2-Sep-2018 | * '''Date''': 2-Sep-2018 | ||
* '''Symptom''': eMMC module is not identified | * '''Symptom''': eMMC module is not identified | ||
− | * '''Applies to''': fitlet2 with serial number 1180902-xxxxx or earlier | + | * '''Applies to''': fitlet2 with SBC serial number 1180902-xxxxx or earlier |
* '''Cause''': Circuit of eMMC interface is not assembled on SBC | * '''Cause''': Circuit of eMMC interface is not assembled on SBC | ||
* '''Workaround''': Use M.2 SATA storage | * '''Workaround''': Use M.2 SATA storage | ||
− | * '''Fix''': Fixed in fitlet2 with serial number 1180903-xxxxx and later | + | * '''Fix''': Fixed in fitlet2 with SBC serial number 1180903-xxxxx and later |
== FITLET2ERR003: fitlet2 does not enter S5 state (off) but only S3 state (sleep) == | == FITLET2ERR003: fitlet2 does not enter S5 state (off) but only S3 state (sleep) == |
Revision as of 13:49, 4 November 2018
Contents
FITLET2ERR001: Power button action cannot be configured in Windows 10
- Date: 27-May-2018
- Symptom: Configuring Power button action through Windows 10 control panel has no effect
- Applies to: fitlet2 rev 1.1
- Cause: Erratum in power management integrated circuit
- Workaround: Control power modes from software
- Fix: Fixed in fitlet2 rev 1.2 with with BIOS version FLT2.0.40.01.00
FITLET2ERR002: No eMMC support
- Date: 2-Sep-2018
- Symptom: eMMC module is not identified
- Applies to: fitlet2 with SBC serial number 1180902-xxxxx or earlier
- Cause: Circuit of eMMC interface is not assembled on SBC
- Workaround: Use M.2 SATA storage
- Fix: Fixed in fitlet2 with SBC serial number 1180903-xxxxx and later
FITLET2ERR003: fitlet2 does not enter S5 state (off) but only S3 state (sleep)
- Date: 23-Oct-2018
- Symptom: When shutting-down fitlet2 from software or by pressing the power button fitlet2 enters S3 (sleep) state instead of S5 (off) state
- Applies to: fitlet2 rev 1.1 with serial number 1180724-xxxxx or earlier
- Cause: An erratum in fitlet2 PMIC
- Workaround: Long press on power button shuts down fitlet2 completely
- Fix: A new version of PMIC used in fitlet2 with serial number 1180725-00001 and later
Note: Amber LED on power button stays on at S5. This is unrelated to FITLET2ERR003